– Installation –
1. When placing the duplex unit back into the tray, hold up the bottom plate
[A] so that the mylar brackets [B] fit under it as shown.
2. Hook the pressure spring [C] to the eccentric cam [D] and the paper lift
arm [E] as shown.
NOTE: When installing the duplex unit, make sure of the following:
a) Positioning pin [F] fits through hole [G] in the side plate.
b) The sensor harness [H] is clamped correctly and is not caught
under the unit frame.
[A]
[C]
[E]
[D]
[B]
[G]
[F]
[H]