3.8 EXPOSURE LAMP VOLTAGE CONTROL
The main board controls the exposure lamp voltage through the ac drive
board. The exposure lamp voltage is based on the base lamp voltage and
various correction factors. The exposure lamp data setting determines the
base lamp voltage. The following table gives the approximate lamp voltage
for each data setting.
Exposure Lamp Data/Voltage Reference Table (SP48)
Exposure
lamp data
Exposure lamp voltage
(standard)
Exposure
lamp data
Exposure lamp voltage
(standard)
115V
machine
220/230/240V
machine
115V
machine
220/230/240V
machine
100
57.1
105.9
126
71.9
133.4
101
57.6
106.9
127
72.5
134.5
102
58.2
108.0
128
73.0
135.5
103
58.8
109.1
129
73.6
136.6
104
59.3
110.1
130
74.2
137.6
105
59.9
111.2
131
74.7
138.7
106
60.5
112.2
132
75.3
139.8
107
61.1
113.3
133
75.9
140.8
108
61.6
114.4
134
76.5
141.9
109
62.2
115.4
135
77.0
142.9
110
62.8
116.5
136
77.6
144.0
111
63.3
117.5
137
78.2
145.1
112
63.9
118.6
138
78.7
146.1
113
64.5
119.6
139
79.3
147.2
114
65.0
120.7
140
79.9
148.2
115
65.6
121.8
141
80.5
149.3
116
66.2
122.8
142
81.0
150.4
117
66.8
123.9
143
81.6
151.4
118
67.3
124.9
144
82.2
152.5
119
67.9
126.0
145
82.7
153.5
120
68.5
127.1
146
83.3
154.6
121
69.0
128.1
147
83.9
155.6
122
69.6
129.2
148
84.4
156.7
123
70.2
130.2
149
85.0
157.8
124
70.8
131.3
150
85.6
158.8
125
71.3
132.4
NOTE: Exposure lamp rating: 115 V machine: 97 V/280 W
220/230/240
V
machine:
180
V/310
W
Default data value: 126
FT4220/4222
2-18
STM
Summary of Contents for FT4215
Page 1: ...FT4220 4222 4215 SERVICE TRAINING MANUAL ...
Page 12: ...SECTION 1 OVERALL MACHINE INFORMATION ...
Page 28: ...8 AC POWER AND DC POWER DISTRIBUTION FT4220 4222 1 16 STM ...
Page 31: ...SECTION 2 DETAILED SECTION DESCRIPTIONS ...
Page 114: ...SECTION 3 DOCUMENT FEEDER ...
Page 138: ...SECTION 4 SORTER ...
Page 157: ...SECTION 5 DUPLEX ...