SC
[Level]
Symptom
Possible Cause/Required Action
[B]
The USB interface cannot be
used due to a driver error.
• Defective USB driver
• Loose connection
1. Check the connection.
2. Replace the controller.
860
[B]
HDD: Initialization error
The controller detects that the
hard disk fails.
• HDD not initialized
• Defective HDD
1. Reformat the HDD (SP5832).
2. Replace the HDD.
861
[D]
HDD: Reboot error
The HDD does not become
ready within 30 seconds after
the power is supplied to the
HDD.
• Loose connection
• Defective cables
• Defective HDD
• Defective controller
1. Check the connection between the HDD and
controller.
2. Check and replace the cables.
3. Replace the HDD.
4. Replace the controller.
863
[D]
HDD: Read error
The data stored in the HDD
cannot be read correctly.
• Defective HDD
• Defective controller
1. Replace the HDD.
2. Replace the controller.
864
[D]
HDD: CRC error
While reading data from the
HDD or storing data in the
HDD, data transmission fails.
• Defective HDD
1. Replace the HDD.
865
HDD: Access error
4. Troubleshooting
118
4
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...