[-50 to 0 / 0 / 1deg /step]
1917 025
GL:L:Temp. Inc.
*EGB
Adjusts the temperature increase for glossary
paper at low temperature.
[0 to 30 / 7 / 1deg /step]
SP2-XXX (Drum)
2101
[Color Regist.] Color Registration Correction
([Color], M: Main scan, S: Sub scan)
You can adjust these SPs if the color registration is not good after the Line Position
Adjustment (also known as ‘MUSIC’) is done. The [K] value (-001) is the standard value
in the main scan adjustment. The values other than [k] value are added to [K] value. So,
[K] value normally does not need to be adjusted in the main scan adjustment.
2101 001
[K]: M Regist. Dot
*EGB
Adjusts the side edge registration by a dot for each
mode.
[-128 to 127 / 0 / 1 dot/step]
2101 002
[M]: M Regist. Dot
*EGB
2101 003
[C]: M Regist. Dot
*EGB
2101 004
[Y]: M Regist. Dot
*EGB
2101 005
[K]: M Reg. SubD
*EGB
Adjusts the side edge registration by 1/16 dot.
[-15 to 15 / 0 / 1sub-dot/step]
2101 006
[K-M]: M Reg. SubD
*EGB
2101 007
[K-C]: M Reg. SubD
*EGB
2101 008
[K-Y]: M Reg. SubD
*EGB
2101 013
[K-M]: S Reg. 600
*EGB
[-128 to 127 / 0 / 1 line/step]
2101 014
[K-C]: S Reg. 600
*EGB
2101 015
[K-Y]: S Reg. 600
*EGB
2101 016
[K-M]: S Reg. 1200
*EGB
2101 017
[K-C]: S Reg. 1200
*EGB
2101 018
[K-Y]: S Reg. 1200
*EGB
2102
[Magnifi. Adj.] Magnification Adjustment
5. Service Tables
168
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...