2912 102
LL: LS: [FC]
*EGB
[0 to 1275 / 400 / 5%/step]
2912 103
MM: LS: [K]
*EGB
[0 to 1275 / 510 / 5%/step]
2912 104
MM: LS: [FC]
*EGB
[0 to 1275 / 435 / 5%/step]
2912 105
HH: LS: [K]
*EGB
[0 to 1275 / 535 / 5%/step]
2912 106
HH: LS: [FC]
*EGB
[0 to 1275 / 445 / 5%/step]
2913
[T2: SP1: Size4] Transfer Roller Current: Correction for Humidity, Special paper1, Paper
width between A5 and A6
(Environment, Process Speed, [Color]) LS: Low Speed, RS: Regular Speed
• The value displayed on the LCD is different from these SP's values. For example,
"20%" on the LCD actually means 100%.
2913 001
LL: RS [K]: 1st
*EGB
[0 to 1275 / 160 / 5%/step]
2913 002
LL: RS [K]: 2nd
*EGB
[0 to 1275 / 220 / 5%/step]
2913 003
LL: RS [FC]: 1st
*EGB
[0 to 1275 / 130 / 5%/step]
2913 004
LL: RS [FC]: 2nd
*EGB
[0 to 1275 / 185 / 5%/step]
2913 005
LL: LS [K]: 1st
*EGB
[0 to 1275 / 135 / 5%/step]
2913 006
LL: LS [K]: 2nd
*EGB
[0 to 1275 / 175 / 5%/step]
2913 007
LL: LS [FC]: 1st
*EGB
[0 to 1275 / 165 / 5%/step]
2913 008
LL: LS [FC]: 2nd
*EGB
[0 to 1275 / 235 / 5%/step]
2913 009
MM: RS [K]: 1st
*EGB
[0 to 1275 / 130 / 5%/step]
2913 010
MM: RS [K]: 2nd
*EGB
[0 to 1275 / 265 / 5%/step]
2913 011
MM: RS [FC]: 1st
*EGB
[0 to 1275 / 125 / 5%/step]
2913 012
MM: RS [FC]: 2nd
*EGB
[0 to 1275 / 310 / 5%/step]
2913 013
MM: LS [K]: 1st
*EGB
[0 to 1275 / 150 / 5%/step]
2913 014
MM: LS [K]: 2nd
*EGB
[0 to 1275 / 300 / 5%/step]
2913 015
MM: LS [FC]: 1st
*EGB
[0 to 1275 / 145 / 5%/step]
5. Service Tables
218
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...