[1 to 3 / 3 / 1 /step]
1: Normal (ON except the line position adjustment
at printout interval)
2: Always ON
3: Always OFF
9911
[TC Initial]
9911 001
Maximum Repeat
*EGB
Adjusts the maximum toner cartridge initializing
time.
[1 to 30 / 15 / 1 /step]
9911 002
Threshold
*EGB
Adjusts the threshold for toner cartridge initializing.
[1 to 100 / 20 / 0.01 V/step]
9912
[ST Sensor]
9912 001
read
*EGB
Adjusts the Vcnt. DFU
9914
[Waste Toner NF] Waste Toner Near Full
Specifies the number of sheets to be printed after waste toner near full.
9914 001
Print 1
*EGB
[0 to 5000 / 1250 / 1/step]
9914 002
Print 2
*EGB
[0 to 5000 / 250 / 1/step]
9914 003
Print 3
*EGB
[0 to 5000 / 125 / 1/step]
9914 004
Print 4
*EGB
Specifies the number of sheets to be printed after
replacing the waste toner bottle.
[0 to 5000 / 2500 / 1/step]
9914 005
Detection Times
*EGB
Displays the times of waste toner near full.
[0 to 50 / 0 / 1 /step]
9914 006
Near Full Count.
*EGB
Displays the total counter for waste toner near full.
[0 to 100000 / 0 / 1 /step]
9918
[LD Pow. Change] LDB Power Change
9918 001
*EGB
[0 or 1 / 0 / -] Alphanumeric
Service Mode Table
317
5
Summary of Contents for G-P3
Page 1: ...Model G P3 Machine Code G190 SERVICE MANUAL January 2008 Subject to change...
Page 11: ...10...
Page 77: ...11 Harness guide C x 2 12 Drive unit D x 6 x 16 3 Replacement and Adjustment 76 3...
Page 91: ...3 Replacement and Adjustment 90 3...
Page 137: ...LEDs No LEDs are used for this model except for the Network Interface 4 Troubleshooting 136 4...
Page 337: ...5 Service Tables 336 5...
Page 411: ...MEMO 410...
Page 412: ...MEMO 411...
Page 413: ...MEMO 412...