SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC681-**
D
Device ID is not identified (toner cartridge)
An error is notified during the ID identification after three retries.
681 - 1 Device ID error (Incorrect ID)
681 - 6 Channel error
681 - 11 Device ID error (No ID chip)
681 - 16 Communication Error
681 - 21 Communication timeout
681 - 26 The device has stopped its operation
681 - 31 The requested buffer is full
681 - 36 EEPROM SRAM OPEN: Verification error
• Turn the main power OFF and then ON.
• Replace the toner cartridge (ID chip)
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC682-**
D
Device ID is not identified (PCDU)
An error is notified during the ID identification after three retries.
682 - 1 Device ID error (Incorrect ID)
682 - 6 Channel error
682 - 11 Device ID error (No ID chip)
682 - 16 Communication Error
682 - 21 Communication timeout
682 - 26 The device has stopped its operation
682 - 31 The requested buffer is full
682 - 36 EEPROM SRAM OPEN: Verification error
• Turn the main power OFF and then ON.
• Replace the PCDU (ID chip)
Service Call
157
Summary of Contents for Gim-MF1a
Page 1: ...Model Gim MF1a b Machine Code M172 M173 Field Service Manual September 2014...
Page 2: ......
Page 32: ...2 Installation 30...
Page 46: ...2 Operation Panel A x 5 4 Replacement and Adjustment 44...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103...
Page 122: ...5 Operation Panel page 43 Operation Panel 4 Replacement and Adjustment 120...
Page 125: ...Service Program Mode 123...
Page 184: ...6 Troubleshooting 182...
Page 192: ...MEMO 190...
Page 193: ...MEMO 191...
Page 194: ...MEMO 192 EN...
Page 195: ...Model Gim MF1a b Machine Code M172 M173 Appendices September 2014...
Page 196: ......
Page 214: ...1 Appendices Specifications 18...
Page 299: ...MEMO 103...
Page 300: ...MEMO 104 EN...