Copier
SM 2-11
M052/M053/M054
Inst
allation
2.3.3 METER CLICK CHARGE
Basically, there are two ways to set up this function.
Meter click charge enabled (SP 5-930-001 set to "enabled") and Parts replacement
operation type enabled (SP5-067-001 set to "0: Service"):
The counter can be displayed and
printed by the customer. The technician can then call the customer and ask them to read the
counter.
Meter click charge disabled (SP 5-930-001 set to "disabled"; this is the default setting)
and Parts replacement operation type enabled (SP5-067-001 set to "1: User", this is the
default setting):
The counter cannot be displayed or printed by the customer. To check the
counter, the technician must print the SMC report (SP 5-990).
You must select one of the counter methods (developments/prints) in accordance with
the contract by using SP5-045-001.
Item
SP No.
Function
Default
Meter Click
Charge Setting
SP5-930-001
Enables or disables Meter Click
Charge.
When enabled:
The counter menu shows
immediately after you push the
"Menu" key. The "Counter
Method" (SP5-045) sets the
type of the counter.
You can print the counter from
the counter menu.
When disabled:
The counter menu does not
show.
"0": OFF
Meter Click
Charge: Life
Disp:
Maintenance Kit
SP5-930-002
Enables or disables the PM alert for
the maintenance kit.
If this SP is enabled, an alert
message is displayed when the
maintenance kit needs to be
replaced.
"0": Off
⇒
Rev. 12/26/2012
Summary of Contents for M052
Page 1: ...M052 M053 M054 SERVICE MANUAL ...
Page 15: ......
Page 20: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Page 21: ......
Page 31: ......
Page 76: ......
Page 77: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 78: ......
Page 82: ......
Page 210: ...1 Bin Tray Unit M052 M053 M054 4 128 SM 10 Remove two screws A ...
Page 214: ......
Page 216: ......
Page 426: ......
Page 466: ......
Page 467: ...ENERGY SAVING REVISION HISTORY Page Date Added Updated New None ...
Page 468: ......
Page 474: ...M052 M053 M054 SERVICE MANUAL APPENDICES ...
Page 475: ......
Page 477: ......
Page 479: ......
Page 495: ......
Page 496: ...APPENDIX PREVENTIVE MAINTENANCE TABLES REVISION HISTORY Page Date Added Updated New None ...
Page 497: ......
Page 501: ...M381 FAX OPTION TYPE SP5200 REVISION HISTORY Page Date Added Updated New None ...
Page 502: ......
Page 506: ......
Page 649: ......
Page 651: ......
Page 653: ......