Energy Save
SM 7-3
M052/M053/M054
Energy
Saving
Find the amount of time spent in each mode (subtract the earlier measurement from the
later measurement).
Multiply this by the power consumption spec for each mode.
Convert the result to kWh (kilowatt hours)
Here is an example calculation.
Machine
Condition
SP8941:
Machine
Status
Time at
Start
(min.)
Time at
End (min.)
Running
time
(hour)
(
-
)/60
=
Power
consumption
Spec. (W)
Power
consumption
(KWH)
(
x
)/1000
=
Operating 001:
Operating
Time 21089.0
21386.0
4.95
898
4.45
Stand by
(Ready)
002:
Standby
Time 306163.0
308046.0 31.38
179
5.62
Energy
save
(Panel off)
003:
Energy
Save
Time 74000
75111.0
18.52
148.09
2.74
Low power 004: Low
Power
Time 148000
150333
38.88
111
4.32
Sleep 005:
Off
Mode
Time 508776.0
520377.0 193.35
1.8
0.35
Total
17.47
Summary of Contents for M052
Page 1: ...M052 M053 M054 SERVICE MANUAL ...
Page 15: ......
Page 20: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Page 21: ......
Page 31: ......
Page 76: ......
Page 77: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 78: ......
Page 82: ......
Page 210: ...1 Bin Tray Unit M052 M053 M054 4 128 SM 10 Remove two screws A ...
Page 214: ......
Page 216: ......
Page 426: ......
Page 466: ......
Page 467: ...ENERGY SAVING REVISION HISTORY Page Date Added Updated New None ...
Page 468: ......
Page 474: ...M052 M053 M054 SERVICE MANUAL APPENDICES ...
Page 475: ......
Page 477: ......
Page 479: ......
Page 495: ......
Page 496: ...APPENDIX PREVENTIVE MAINTENANCE TABLES REVISION HISTORY Page Date Added Updated New None ...
Page 497: ......
Page 501: ...M381 FAX OPTION TYPE SP5200 REVISION HISTORY Page Date Added Updated New None ...
Page 502: ......
Page 506: ......
Page 649: ......
Page 651: ......
Page 653: ......