SH-MF1 Training
51
Slide 51
PM Counter Reset
User Maintenance Mode (default)
If the machine is set for user maintenance, all PM
counters are automatically reset when
maintenance kit parts are replaced.
Service Maintenance Mode (click charge set to
ON with SP5930-001, and SP5067-001 set to 0)
The fusing unit counter resets automatically.
The following counters must be reset manually
using SP7804.
» All clear: SP7804-002
» Transfer roller: SP7804-004
» Feed roller: SP7804-005
You can do a forced reset of the fusing unit with
SP7804-003. (Useful if using a rebuilt fusing unit.)
Refer to "New Fusing Unit Detection" in the fusing section of this course.
SP5067-001 selects service maintenance or user maintenance. (1 = User
maintenance, 0 = Service maintenance, default = 1)
Summary of Contents for M052
Page 3: ...SH MF1 Training 3 Slide 3 PRODUCT OUTLINE Introduction No additional notes ...
Page 12: ...SH MF1 Training 12 Slide 12 Product Outline New Features No additional notes ...
Page 22: ...SH MF1 Training 22 Slide 22 Product Outline Options No additional notes ...
Page 45: ...SH MF1 Training 45 Slide 45 Transporting the Machine No additional notes ...
Page 47: ...SH MF1 Training 47 Slide 47 Maintenance No additional notes ...
Page 87: ...SH MF1 Training 87 Slide 87 Scanner No additional notes ...
Page 112: ...SH MF1 Training 112 Slide 112 Laser Exposure No additional notes ...
Page 117: ...SH MF1 Training 117 Slide 117 All In One Cartridge AIO ...
Page 127: ...SH MF1 Training 127 Slide 127 Fusing No additional notes ...
Page 135: ...SH MF1 Training 135 Slide 135 Paper Exit No additional notes ...
Page 167: ...SH MF1 Training 167 Slide 167 One bin Tray M053 only No additional notes ...