102
PE-MF3/PE-P2 Training
Slide 102
After you Replace the Laser Optics Housing Unit (4)
If MUSIC was not successful, do the
following.
1. Open the upper cover and check
the lot number of the laser optics
housing unit.
2. Check to see if this lot number is
listed in any of the Excel files that
are supplied periodically. If it is,
then do the rest of this procedure.
3. Open the front cover and turn on
the machine.
4. Input the setting values for the
laser optics housing unit with "LSU
Adjustment” in the "Engine
Maintenance" menu.
5. Close the front cover.
6. Execute "Color Registration" in the
"Engine Maintenance" menu.
7. Turn the main switch off/on.
MUSIC will be performed
automatically.
Steps 3 to 7 are a repeat of slide 1 of this procedure, except that we use the
numbers from the excel file, and not from the printed sheet that comes with the