6.Troubleshooting
295
SC900 (Others)
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC900-00
D
Electronic counter error
The electronic total counter value is not the specified value.
This error is detected when the counter moves forward.
The NVRAM connection is not correct.
The NVRAM is defective.
The NVRAM data is corrupted.
The data was written in the wrong area due to external factors.
When PRT received signals at SRM, the requested count is not completed.
Replace the NVRAM.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC990-
00
D
Software performance error
The software attempted to make an unexpected operation.
Incorrect argument
Incorrect internal parameter
Insufficient working memory
Abnormal performance caused by an error that cannot be detected in normal SC detection
due to hardware specifications.
Turn the main power switch off and on.
Reinstall the software of the controller board.
Reinstall the software of the engine board.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC991-
00
C
Software Error (Operation Can Continue)
The software performed in an unexpected way. By taking recovery measures, further operation
is possible.
The parameter is invalid.
There is insufficient work memory.
This SC is caused by errors that are not normally detected from the hardware.
Not required
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC992-00
D
Undefined SC
An undefined SC has occurred.
There is a bug in the software.
Summary of Contents for M0A0
Page 2: ......
Page 10: ...8 ...
Page 12: ......
Page 34: ...2 Installation 22 9 Enter the password 10 Press OK 11 Enter the password again ...
Page 85: ...2 Installation 73 ...
Page 189: ...4 Replacement and Adjustment 177 ...
Page 203: ...5 System Maintenance 191 SP Mode Tables See Appendices ...
Page 229: ...5 System Maintenance 217 LDAP authorization information ...
Page 344: ...7 Detailed Descriptions 332 side guides from side to side ...
Page 358: ...7 Detailed Descriptions 346 ...
Page 368: ......
Page 558: ......
Page 574: ...1 Replacement and Adjustment 16 7 LCD A 4 8 Microphone A cushioning 1 ...
Page 622: ......
Page 624: ... A Short Edge Feed SEF B Long Edge Feed LEF ...
Page 626: ......
Page 632: ...1 Installation 6 ...
Page 752: ...5 Detailed Section Descriptions 126 Report Sample ...
Page 758: ...6 Specifications 132 Fax Unit Configuration Component No Remarks FCU 1 Speaker 2 ...
Page 760: ......
Page 762: ......
Page 776: ...2 Replacement and Adjustment 14 4 Detach the paper size switch from the bracket A Hook x2 ...