3.Troubleshooting
17
Code
Meaning
Suggested Cause/Action
sending CI.
ANSam was too short to detect.
Check the line connection and condition.
Try making a call to another V.8/V.34 fax.
0-75 The called terminal fell back to T.30 mode,
because it could not detect a CM in
response to ANSam (ANSam timeout).
The terminal could not detect ANSam.
Check the line connection and condition.
Try receiving a call from another V.8/V.34 fax.
0-76 The calling terminal fell back to T.30 mode,
because it could not detect a JM in
response to CM
(CM timeout).
The called terminal could not detect a CM due to noise,
etc.
Check the line connection and condition.
Try making a call to another V.8/V.34 fax.
0-77 The called terminal fell back to T.30 mode,
because it could not detect a CJ in response
to JM
(JM timeout).
The calling terminal could not detect a JM due to noise,
etc.
A network that has narrow bandwidth cannot pass JM
to the other end.
Check the line connection and condition.
Try receiving a call from another V.8/V.34 fax.
0-79 The called terminal detected CI while
waiting for a V.21 signal.
Check for line noise or other line problems.
If this error occurs, the called terminal falls back to T.30
mode.
0-80 The line was disconnected due to a timeout
in V.34 phase 2 – line probing.
The guard timer expired while starting these phases.
Serious noise, narrow bandwidth, or low signal level
can cause these errors.
If these errors happen at the transmitting terminal:
Try making a call at a later time.
Try using V.17 or a slower modem using dedicated tx
parameters.
Try increasing the tx level.
Try adjusting the tx cable equalizer setting.
If these errors happen at the receiving terminal:
Try adjusting the rx cable equalizer setting.
Try increasing the tx level.
Try using V.17 or a slower modem if the same error is
frequent when receiving from multiple senders.
0-81 The line was disconnected due to a timeout
in V.34 phase 3 – equalizer training.
0-82 The line was disconnected due to a timeout
in the V.34 phase 4 – control channel start-
up.
0-83 The line was disconnected due to a timeout
in the V.34 control channel restart
sequence.
0-84 The line was disconnected due to abnormal
signaling in V.34 phase 4 – control channel
start-up.
The signal did not stop within 10 s.
Turn off the main power switch, then turn it back on.
If the same error is frequent, replace the FCU.
0-85 The line was disconnected due to abnormal
signaling in V.34 control channel restart.
The signal did not stop within 10 s.
Turn off the main power switch, then turn it back on.
Summary of Contents for M0A0
Page 2: ......
Page 10: ...8 ...
Page 12: ......
Page 34: ...2 Installation 22 9 Enter the password 10 Press OK 11 Enter the password again ...
Page 85: ...2 Installation 73 ...
Page 189: ...4 Replacement and Adjustment 177 ...
Page 203: ...5 System Maintenance 191 SP Mode Tables See Appendices ...
Page 229: ...5 System Maintenance 217 LDAP authorization information ...
Page 344: ...7 Detailed Descriptions 332 side guides from side to side ...
Page 358: ...7 Detailed Descriptions 346 ...
Page 368: ......
Page 558: ......
Page 574: ...1 Replacement and Adjustment 16 7 LCD A 4 8 Microphone A cushioning 1 ...
Page 622: ......
Page 624: ... A Short Edge Feed SEF B Long Edge Feed LEF ...
Page 626: ......
Page 632: ...1 Installation 6 ...
Page 752: ...5 Detailed Section Descriptions 126 Report Sample ...
Page 758: ...6 Specifications 132 Fax Unit Configuration Component No Remarks FCU 1 Speaker 2 ...
Page 760: ......
Page 762: ......
Page 776: ...2 Replacement and Adjustment 14 4 Detach the paper size switch from the bracket A Hook x2 ...