4.Service Tables
100
Address
Function
Unit
Remarks
6805E5
Bits 0 to 6 – Not used
Bits 7 – Energy saving for DSP, COMBLK, SiDAA
0: Does not save energy
1: Saves energy
NOTES
1.
If a setting is not required, store FF in the address.
2.
Italy and Belgium only
RAM address 68055E: the lower four bits have the following meaning.
Bit 2 - 1: International dial tone cadence detection enabled (Belgium)
Bit 1 - Not used
Bit 0 - 1: PSTN dial tone cadence detection enabled (Italy)
If bit 0 or bit 2 is set to 1, the functions of the following RAM addresses are changed.
680508 (if bit 0 = 1) or 680538 (if bit 2 = 1): tolerance for on or off state duration (%), and number of cycles
required for detection, coded as in address 680533.
68050B (if bit 0 = 1) or 68053B (if bit 2 = 1): on time, hex code (unit = 20 ms)
68050C (if bit 0 = 1) or 68053C (if bit 2 = 1): off time, hex code (unit = 20 ms)
3.
Pulse dial parameters (addresses 68054A to 68054F) are the values for 10 pps. If 20 pps is used, the machine
automatically compensates.
4.
The first ring may not be detected until 1 to 2.5 wavelengths after the time specified by this parameter.
5.
The calculated level must be between 0 and 10.
The attenuation levels calculated from RAM data are:
High frequency tone:
– 0.5 x N
680552
/
680554
–3.5 dBm
– 0.5 x N
680555
dBm
Low frequency tone:
– 0.5 x (N
680552
/
680554
+ N
680553
) –3.5 dBm
– 0.5 x (N
680555
+ N
680553
) dBm
N
680552
, for example, means the value stored in address 680552(H)
6.
68054A: Europe - Between Ds opening and Di opening, France - Between Ds closing and Di opening
68054D: Europe - Between Ds closing and Di closing, France - Between Ds opening and Di closing
7.
Tone signals which frequency is lower than 1500Hz (e.g., 800Hz tone for AI short protocol) refer to the setting at
6805B5h. Tones which frequency is higher than 1500Hz refer to the setting at 6805B6h.
8.
68054A, 68054D, 68054E: The actual inter-digit pause (pulse dial mode) is the sum of the period specified by
the RAM addresses 68054A, 68054D, and 68054E.
Summary of Contents for M0A0
Page 2: ......
Page 10: ...8 ...
Page 12: ......
Page 34: ...2 Installation 22 9 Enter the password 10 Press OK 11 Enter the password again ...
Page 85: ...2 Installation 73 ...
Page 189: ...4 Replacement and Adjustment 177 ...
Page 203: ...5 System Maintenance 191 SP Mode Tables See Appendices ...
Page 229: ...5 System Maintenance 217 LDAP authorization information ...
Page 344: ...7 Detailed Descriptions 332 side guides from side to side ...
Page 358: ...7 Detailed Descriptions 346 ...
Page 368: ......
Page 558: ......
Page 574: ...1 Replacement and Adjustment 16 7 LCD A 4 8 Microphone A cushioning 1 ...
Page 622: ......
Page 624: ... A Short Edge Feed SEF B Long Edge Feed LEF ...
Page 626: ......
Page 632: ...1 Installation 6 ...
Page 752: ...5 Detailed Section Descriptions 126 Report Sample ...
Page 758: ...6 Specifications 132 Fax Unit Configuration Component No Remarks FCU 1 Speaker 2 ...
Page 760: ......
Page 762: ......
Page 776: ...2 Replacement and Adjustment 14 4 Detach the paper size switch from the bracket A Hook x2 ...