ADC Calibration
PC Calibration
After the Main Board is changed, PC Calibration should be done as well.
• Test equipment: video generator
• Test signal analog: 800 x 600@60Hz
• Test Pattern:94% White (up)/6% Black (down) (See below.)
Calibration Procedure
1.
Press the "power" -> “up” -> "right" -> "up" -> "left" -> "Menu" buttons sequentially to get
into service mode.
2.
Choose "Calibration" and press the "Enter" button, then select "PC Calibration".
When "Success" appears, it means "ADC Calibration" is OK.
3.
Choose "Menu" or "Exit" to leave service mode.
3. Adjustment
40