Troubleshooting
166
4
-
If master misfeeds occur
frequently
If the master misfeeds frequently,
fragments of the master might be left
in the bottom of the master tray. Re-
move the fragments.
A
Slide out the master tray.
B
Open the cover at the bottom of
the master tray while holding the
lever and remove the fragments.
C
Close the cover and slide in the
master tray.
Note
❒
Make sure that you securely
close the cover before sliding in
the master tray.
“
x
+ B + E” Master Misfeeds
in the Master Eject Section
A
Open the front cover.
B
Push the drum unlocking switch
to unlock the unit.
C
Lower drum unit lock lever (B1).
D
Take out the drum.
Note
❒
For taking out the drum unit,
see p.134 “Changing the Colour
Drum Unit”.
ACY048S
ZFXH201E
AUX115S
AUX116S
AUX117S
AUX118S