This setting is valid if [SADF] is specified for [Original Feed Type] when scanning.
If [Set Wait Time] is selected, enter the wait time in seconds (3-999) for placing additional originals
with the number keys. Scanning will start automatically if additional originals are placed within this
time. You can end scanning and begin transmission by pressing the [ ] key within this time. Once
the specified time has elapsed, transmission starts automatically.
If [Continuous Wait] is selected, the machine will wait for the additional originals until the [ ] key is
pressed. Scanning will start when additional originals are placed and the [Start] key is pressed. You
can end scanning and begin sending by pressing the [ ] key.
Even if originals are placed on the exposure glass, the machine will operate according to the specified
settings. However, every time originals are placed on the exposure glass, you must press the [Start]
key to start scanning. Scanning will start if additional originals are placed and the [Start] key is pressed
within this time. You can end scanning and begin transmission by pressing the [ ] key within this time.
Once the specified time has elapsed, transmission starts automatically.
If originals are placed in the auto document feeder (ADF), transmission will start without waiting for
additional originals after all originals in the ADF have been scanned, regardless of the specified
settings.
If a paper misfeed occurs or any of the following operations are performed while the machine is
waiting for additional originals, the countdown stops and does not start again until the [ ] key is
pressed.
• Changing the settings such as the scan settings
• Opening the upper cover of the ADF
• Pressing the [Interrupt] key to activate the copy mode
Background Density of ADS (Full Color)
Characteristics due to the type of paper such as nonwhiteness like newspaper or transparent originals
can be reduced by correcting the scanning density.
The default setting is the middle of 5 adjustment levels.
5. Scanner Features
108
5
Summary of Contents for Pro C720s
Page 14: ...12...
Page 32: ...1 Connecting the Machine 30 1...
Page 40: ...p 9 Accessing User Tools 2 System Settings 38 2...
Page 62: ...2 System Settings 60 2...
Page 80: ...3 Tray Paper Settings 78 3...
Page 93: ...p 9 Accessing User Tools Edit 91 4...
Page 121: ...8 Press the User Tools key Registering Names 119 6...
Page 168: ...6 Registering Addresses and Users for Scanner Functions 166 6...
Page 174: ...7 Other User Tools 172 7...
Page 209: ...MEMO 207...
Page 210: ...MEMO 208 EN USA D016 6949...
Page 212: ...Operating Instructions General Settings Guide D016 6949 EN USA...