4-2
Confidential
1.1 Setting by Spec, Setting Serial Number and
Entering Adjusted Value of Laser Unit
<Operating Procedure>
(1) Enter the maintenance mode.
(2) Connect the machine to your computer using the USB cable.
When you use the main PCB ASSY that has been used even once in the market (the
machine is at factory shipping state (Shipping state=ON).), perform the following steps
(3) and (4). When the new main PCB ASSY is used, proceed to step (5).
(3) Open the temporary folder and double-
click “MemoryAccessTool.exe”. The
screen shown on the right appears.
(4) Click the [Execute] and close the
Maintenance Exception Tool screen.
Wait for 5 seconds or longer and then
proceed to the next step.
(5) Double-click “SvSettingTool.exe”. The screen
shown on the right appears.
(6) Check that the USB port connected with the
machine is displayed in the box (A).
(7) Enter the model name in the box (B) and press
the [Find a model]. Series name and model name
are displayed in the box (C). If the connected
product name is not displayed, keep pressing the
[Find a model] until it shows up.
Note:
• If the [Execute] on the Memory access tool is pressed once, it is valid as long as the
machine does not quit the maintenance mode.
• If the BRMODELCODE, the Serial, and the ID fields are displayed incorrectly, quit the
maintenance mode and then restart from step (1).
(A)
(B)
(C)
(D)
(E)