4.7.4 Drum error
<User Check>
• Clean the corona wire of the drum unit.
• Replace the drum unit with a new one.
4.7.5 Drum replacement message displayed on LCD is not cleared
<User Check>
• Reset the drum counter according to the manual.
Step
Cause
Remedy
1
Dirt on the electrodes of the
drum unit and those of the
machine
Clean the electrodes of the drum unit and
those of the machine. (Refer to
and
2
Dirt on the electrodes of the
high-voltage power supply
PCB and those of the machine
Clean the electrodes of the high-voltage
power supply PCB and those of the machine.
3
High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
4
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.