3-29
Confidential
8.12 New toner sensor PCB ASSY
(1) Disconnect the New toner sensor flat cable from the High-voltage power supply PCB
ASSY, and release the Hook to remove the New toner sensor PCB ASSY. Disconnect the
Registration front/rear sensor harness from the New toner sensor PCB ASSY.
Fig. 3-24
Harness routing: Refer to
.
New toner sensor flat cable
Hook
Registration front/rear sensor harness
<Front side>
New toner sensor PCB ASSY
High-voltage power
supply PCB ASSY