5-26
Confidential
1.3.14 Setting by spec (Function code 74)
<Function>
This function is used to customize the machine according to language and function settings.
<Operating Procedure>
(1) Press the [
▲
] or [
▼
] in the initial state of maintenance mode to display “MAINTENANCE
74” on the LCD, and press the [OK]. The country code currently set is displayed on the
LCD (The first digit is flashing).
(2) Press the [
▲
] to enter “1”, or the [
▼
] to enter “0”. Then press the [OK]. The second digit
starts to flash.
(3) Press the [
▲
] to enter “1”, or the [
▼
] to enter “0” similarly. Then press the [OK]. The
second digit is completed and the fourth digit starts to flash.
(4) The third digit and fourth digit changes at once when the [
▲
] or [
▼
] is pressed. Press
the [Go] when the desired value is shown on the LCD. The new setting is saved, and
“PARAMETER INIT” is displayed on the LCD. The machine then returns to the initial
state of maintenance mode.
Setting by spec code list
SP 230D
EUR : 0003
SP 230DNw EUR : 0003
Note:
• If there is no entry for one minute or longer, the machine returns to the initial state of
maintenance mode automatically, regardless of the display status.
• The spec code list above is current as of October 2017.