1.Detailed Descriptions
40
the near-end status is notified to the machine.
To correctly count the actual remaining number of staples, instruct the customer to do as follows:
•
Replace the cartridge after the staples have completely run out (End).
•
Replace the cartridge with the machine’s power on (so that the device status can be monitored).
What if the counter does not match the actual remaining number of staples?
•
After replacing the cartridge, set SP6-795-002 / SP6-796-002 (Staple N.E. Setting: Staple
Remaining Setting) to the maximum value.
•
If some degree of mismatch is tolerable, change the value according to the estimated number of
remaining staples in the new cartridge.
Automatic Counter Reset
After reaching the near-end status, if the staples do not run out (End) even after the number of staples
used exceeds 1.5 times that of the specified number of staples in the near-end status, the counter is
automatically reset according to the determination that the staples have been replaced. The automatic
counter reset function can be set on/off on the corresponding SP.
SP6-796-003/007 (Staple N.E. Setting: Anomaly Near-End Disp. Clear Setting)
0: Reset
1: Do not reset
Saddle Stitching (Booklet Stapling)
A New Type of Saddle Stitching
Compared to normal center stapling, center stapling with this finisher can reduce the bulge at the center
of the booklet.
[A] Common saddle stitching
[B] Saddle stitching with this finisher