T
echnical
B
ulletin
PAGE: 1/2
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
24-Oct-2011
No.:
RD074028
Subject:
Field Service Manual Correction (SC681)
Prepared by:
T. Komori
From:
1st Tech Service Sect., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (
)
Tier2
Service Manual Correction
6. Troubleshooting > SC Tables > SC600: Communications > SC681 Toner Cartridge
RFID Communication Error
No.
Sub code
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
RFID: Communication error due to the following:
Poor connection with harness that connects RFID controller board
and BCU board
Defective RFID controller board.
Defective BCU board
Electrical noise
001 ~ 005
D
Check the connection of the harness that runs between the RFID
controller board and BCU board.
Check the connection of the GND line for the ITB unit.
Check the physical condition of this harness and replace it if it is
damaged.
Replace the RFID controller board.
Replace the BCU board
RFID: Communication error due to the following:
Defective RFID reader and writer
Defective RFID controller board
Electrical noise
061 ~ 064
D
Replace the toner cartridge for the affected color (See table below).
Replace the BCU board
Replace the RFID controller board.
RFID: Communication error due to the following:
Defective RFID reader and writer
Defective RFID controller board
Electrical noise
071 ~ 074
D
Replace the toner cartridge for the affected color (See table below).
Replace the RFID controller board.
RFID: Communication error due to the following:
Defective RFID reader and writer
Electrical noise
681
081 ~ 164
D
Replace the toner cartridge for the affected color (See table below).
If the SC still occurs, see note below.