T
echnical
B
ulletin
PAGE: 4/6
Reissued:01-Dec-11
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
13-Sept-2011
No.:
RD074022a
Production of December 2011 ~
Optimum registration adjustment in the sub scan direction is defined in SP1501-001
instead of SP1001.
For example, the initial SP values are defined as follows.
Current Specification
Modified Specification
SP1501-001 Not
Used
0.6
SP1001-001 0.6
0
SP1001-002 0.6
0
SP1001-003 0.6
0
SP1001-004 0.5
-0.1
SP1001-005 0.4
-0.2
SP1001-006 0.6
0
SP1001-007 0.5
-0.1
SP1950/1951-001 0
0
SP1950/1951-002 0
0
… 0
0
SP1950/1951-100 0
0
Taking the above for an example, the optimum registration adjustment value in the sub
scan direction “0.6” defined at the factory will automatically apply to all custom papers.
Adjustments to SP1001, SP1951, and SP1952 will allow even further fine tuning.
i.e.
Front Side
Back Side
Paper Weight 1
0
+ 0.6
0
+ 0.6
Paper Weight 4
-0.1
+ 0.6
-0.1
+ 0.6
Custom Paper 1
0
+ 0.6
0
+ 0.6