T
echnical
B
ulletin
PAGE: 5/6
Reissued:01-Dec-11
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
13-Sept-2011
No.:
RD074022a
Updating F/W for Units of Production Prior to December 2011
Registration values currently saved in SP1001 will remain even after the f/w update, to
avoid unwanted changes. The default value of SP1501-001 is set to “0” for this reason.
This is an example.
Before f/w update
After f/w update
SP1501-001 None
0
SP1001-001 0.6
0.6
SP1001-002 0.6
0.6
SP1001-003 0.6
0.6
SP1001-004 0.5
0.5
SP1001-005 0.4
0.4
SP1001-006 0.6
0.6
SP1001-007 0.5
0.5
SP1950/1951-001 0.5
0.5
SP1950/1951-002 0.4
0.4
…
SP1950/1951-100 0
0
i.e.
Front Side
Back Side
Paper Weight 1
0.6
+ 0
0.6
+ 0
Custom Paper 1
0.5
+ 0
0.5
+ 0
IMPORTANT
Modification of SP1501 will affect the registration in the sub scan direction
for ALL paper.
If the registration needs to be adjusted for certain paper types only, modify
SP1001 (for generic paper) or SP1950/SP1951 (for custom paper).