T
echnical
B
ulletin
PAGE: 1/1
Model:
Taurus-C1a/C1b (D074/D075)
Date:
12-Jan-12
No.:
RD074039
Subject:
Service Manual Revision: SC995
Prepared
by:
Shinnosuke Sasaki
From:
1st Tech Service Sect., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other (
)
Action required
Service manual revision
Retrofit information
Tier 2
Please add the following description to your Taurus field service manual in the section:
6. Troubleshooting
>
SC Tables
>
SC900: Other.
Added Description
SC995 table
Serial Number Setting Incorrect
SC995
The 11-digit serial number is printed on the data
plate. This information is compared
with the installed components to detect
mismatches.
D
Serial Number Mismatch 1
SC995-01
z
Enter the correct information for the
model with SP5811 or use the
previous NVRAM.
z
Cycle the machine off/on.
D NVRAM
Mismatch
SC995-02
Use the previous NVRAM.
-or-
If the NVRAM must be replaced:
z
Prepare an SD card with the current
model information.
z
Do SP5825 to download the new
model information from the SD card
to new NVRAM.
z
Remove the SD card.
z
Cycle the main machine off/on.
D
Controller Mismatch, or Controller Board
Defective
SC995-03
You must install the CTL controller board
designed for use with this machine.
D
Serial Number Mismatch 2
SC995-04
Reinstall the components which have
been removed from the machine.
Note
One example of a case where the above SC occurs is when a control board for the 65cpm
machine is mistakenly installed in a 75cpm machine or vice versa. (SC995-03 could be
initiated in this case.)