T
echnical
B
ulletin
PAGE: 1/1
Model:
Taurus-C1/P1
Date:
13-Feb-12
No.:
RD074043
Subject:
Service Manual Correction (SC599)
Prepared
by:
Shinnosuke Sasaki
From:
1st PP Tech Service Sec., PP Tech Service Dept.,
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (Manual
Correction)
Tier 2
Please apply the following corrections to your Taurus field service manual in the section:
6. Troubleshooting > SC Tables > SC500: Paper Feed, Transport, Duplexing
Correction
Correct:
SC599
Cooling Box Sensor Error
The cooling box sensor detects unusual values.
z
The cooling liquid dropped below the threshold
z
Connector disconnected or defective
z
IOB
defective
z
Harness
shorted
Incorrect
: The following description in the current FSM is incorrect
Note
The possible actions for this SC are as follows:
z
Fix the leak and refill the liquid.
z
Reconnect
the
connectors.
z
Replace the sensor.
z
Replace the IOB board.
z
Replace the harness.