T
echnical
B
ulletin
PAGE: 2/2
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
26-Mar-12
No.:
RD074056
D
Action
Check the condition of the molded coupling on your next service visit and apply grease to
both couplings, molded and metal.
If the molded coupling [C] is already damaged or broken, replace it with a new one and
apply grease to both couplings.
Use the following grease.
P/No. 54479078 "HEAT RESISTING GREASE MT-78"
Metal coupling [D] interlocks with the molded coupling [C] when the Right Drawer Unit is set in the
mainframe. However, if the couplings are not engaged properly, the metal coupling cannot retract
(in the direction indicated with the arrow in the photo above right) and absorb the pressure when
the drawer is pushed in, causing damage to the molded coupling.