T
echnical
B
ulletin
PAGE: 1/9
Reissued: 30-Nov-15
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
20-Jul-12
No.:
RD074081b
RTB Reissue
The item in
bold italics
were corrected or added.
Subject:
Troubleshooting SC26x
Prepared by:
A.Tajima
From:
1st PP Technical Service Section
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (
)
Tier 2
Symptom
SC265 Skew Control: Out of Range Error (C)
SC266 Skew Control: Out of Range Error (M)
SC267 Skew Control: Out of Range Error (Y)
Note
SC26x is logged internally and does not appear on the operation panel. The symptom
can be noticed by SC285 as a result of SC26x that occur in series.
Cause
Defective skew motor
Action
Replace the skew motor p/n
D0741920
(DC STEPPER MOTOR:ASS'Y) by following the
procedure described below.