T
echnical
B
ulletin
PAGE: 11/14
Model:
Taurus-C1 (D074/D075)
Date:
22-Jun-2011
No.:
RD074015a
Correction 7:
Added Missing Descriptions in SC Tables
Troubleshooting > SC Tables
Descriptions in
red
have been added and corrected for the following SC tables:
SC260
C
Laser Thermistor Error (
C/K
)
SC262
C
Laser Thermistor Error (
Y/M
)
One of the following occurred:
•
The reading of the thermistor in the
CK/YM
laser unit was
less than 10
°
C (50
°
F), indicating that the thermistor
has disconnected.
•
The reading of the thermistor in the
CK/YM
laser unit was
more than 80
°
C (176
°
F), indicating that the thermistor
has shorted out.
•
Cycle the machine off/on
•
IOB harness loose, disconnected, broken, defective
•
CK/YM
laser unit defective
•
IOB defective
SC576
A
Hot Roller NC Sensor (Sensor 7) Poor Connection
The hot roller NC sensor (infrared thermistor) on top of
the fusing unit detected temperature less than 0C for 75
sec.
•
Do SP5810 to cancel the fatal error
•
Sensor disconnected
•
Sensor connector harness or connector broken or
defective
SC579
A
Thermistor 8 Error:
Poor
Connection
Temperature detected at less than 0
°
C.
Note: This is the contact thermistor at the top rear of the
fusing unit
•
Do SP5810 to cancel the fatal error
•
Harness disconnected or broken
•
Poor contact with surface of heating roller
•
Thermistor defective