T
echnical
B
ulletin
PAGE: 1/2
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
13-Sep-2012
No.:
RD074090
Subject:
Field Service Manual Correction (SC684)
Prepared by:
S. Sasaki
From:
1st Tech Service Sect., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other (
)
Action required
Service manual revision
Retrofit information
Tier2
Service Manual Correction
Please add the following descriptions to your Taurus field service manual in the section:
6. Troubleshooting > SC Tables > SC600: Communications > SC684 Fusing Unit ID
Chip Error
No.
Sub code
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Fusing Unit ID Chip Error: ID error
The system made three unsuccessful attempts to communicate with the
fusing unit ID chip.
ID chip data corrupted
Disconnected
Interface
ID chip missing
Electrical
noise
001, 009,
011, 019
D
Replace the Fusing Unit
Cycle the machine off/on
Fusing Unit ID Chip Error: Channel Error
The system made three unsuccessful attempts to communicate with the
fusing unit ID chip.
ID chip data corrupted
Disconnected
Interface
ID chip missing
Electrical
noise
002, 012,
020
D
Replace the Fusing Unit
Cycle the machine off/on
Fusing Unit ID Chip Error: Device Error
The system made three unsuccessful attempts to communicate with the
fusing unit ID chip.
ID chip data corrupted
Disconnected
Interface
ID chip missing
Electrical
noise
003, 013,
021
D
Replace the Fusing Unit
Cycle the machine off/on
Fusing Unit ID Chip Error: Interfered Communication
The system made three unsuccessful attempts to communicate with the
fusing unit ID chip.
SC684
004, 014,
022
D
ID chip data corrupted
Disconnected
Interface
ID chip missing
Electrical
noise