T
echnical
B
ulletin
PAGE: 1/1
Model:
Taurus C1/P1 (D074/D075/M044)
Date:
26-Nov-2012
No.:
RD074094
Subject:
SC672 Description Added to FSM
Prepared by:
K. Tsutsui
From:
1
st
PP Tech Service Sec., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (
)
Tier2
Please add the following description to your Taurus field service manual in the section:
6. Troubleshooting
>
SC Tables
>
SC600: Communications
SC672
D
Controller-to-operation panel communication error at startup
GW
After powering on the machine, the communication circuit between the controller and
the operation panel is not opened, or communication with controller is interrupted after
a normal startup.
z
Controller
stall
z
Controller board installed incorrectly
z
Controller board defective
z
Operation panel connector loose or defective
1. Check the harness connection.
2. Check the board installation.
3. Replace the controller board.