T
echnical
B
ulletin
PAGE: 1/4
Reissued:12-Feb-14
Model:
Taurus-C1a/C1b (D074/D075)
Date:
22-Aug-11
No.:
RD074019a
RTB Reissue
The items in
bold italics
were corrected or added.
SYMPTOM
Banding (uneven density) at 50mm intervals
CAUSE
Cause
Solution
Gap between the drum and
development roller
fluctuates.
Drive gear and coupling
gear of the development
roller are misaligned.
Align the drive gear and
coupling gear. (Step 1)
Development unit is of the
old type (D0742301-03).
Replace with the latest
development unit. (Step 4)
Development unit was
damaged during transport.
Machine usage conditions
Toner/developer
degradation
Refresh toner. (Steps 2&3)
Replace developer. (Step 4)
Recommended Action
Step1:
Are the markings on the drive gear and coupling gear of the development roller
aligned?
Yes :
Go to step 2.
No : Do the
“Development roller Drive gear – Coupling gear alignment
procedure
” described in the last part of this bulletin.
Print the image showing the problem. Has the problem been resolved?
Yes :
Finished.
No : Go to step 2.
Subject:
Troubleshooting procedures for Banding (uneven
density in 50mm pitch)
Prepared by:
Hiroshi Inenaga
From:
PP Tech Service Dept., 1st PP Tech Service Sect.
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other (
)
Action required
Service manual revision
Retrofit information
Tier2