Background
The “pre near end” alert message that appears on the operation panel tends to cause the
users to replace the toner bottler earlier than the appropriate timing, and as a result, toner
could be wasted. The new firmware will delay the display of “pre near end” to correspond
with the “near end” alert timing of the ProC901/C901s series as shown in the diagram
below.
* Number of pages is based on the following print conditions: A4, 8.75% coverage, 25 P/J
Notes on limitations:
The new default value of 3% does not appear in the SP.
Current controller firmware (System/Copy ver1.13 or older for Copier, System ver1.07
or older for Printer) only supports an adjustment range of 10%~100%.
DO NOT
modify these SP values. Modifying these SP values will set the default value
back to 10%. Once modified, the new default value of 3% cannot be retrieved.
Modify these SP values only when they need to be set to a value higher than 10%,
which should be decided based on the job operation requested by your customer.
The above limitations will be resolved in the succeeding controller firmware version to
be released.