T
echnical
B
ulletin
PAGE: 2/2
Model:
Taurus-C1a/C1b (D074/D075)
Date:
5-Dec-13
No.:
RD074110
IMPORTANT
z
Make sure to follow the above procedure. The PM counter values and calculations will
be disrupted, if you failed to follow the procedure.
z
The above procedure does not have to be performed if the fusing units are simply
swapped without replacing any PM parts.
NOTES
z
Take note that in the first example, fusing unit B is set and the machine is power
cycled despite the PM parts replacement is performed only for fusing unit A. This is
necessary because the counter information stored in the ID chip installed on fusing
unit A needs to be updated, which is possible only by re-detecting the s/n of fusing unit
A after detecting the s/n of fusing unit B. (The ID chip performs complex calculations
and stores counter value data in several categories by statuses of the unit rather than
simply counting up the pages.)
z
Setting ON the “Manual New Unit Set” SP is necessary to clear the counter data