The following procedure was deleted as grease application for the Flanges is unnecessary.
11. Before you remove the hot roller, cut out the pattern shown above. (You will need this to remove the
hot roller.)
12. Tape the short edges (60 mm) together with a strip of tape to form a sleeve.
• Use moderately thick paper, but it should bend easily.
• This cutout will protect the hot roller from contamination by grease as it is removed.
13. While the hot roller is still inside the fusing belt, slide the cutout over the hot roller.
14. While holding the cutout at [A] so that it does not move, pull out the hot roller [B].