6.5 Safety functions and stop functions
The SynCore RW unit has the safety functions and stop functions that follow:
1.
Phase detection to protect from a change of phases in the power supply. This makes sure that
the direction-of-rotation of the motor gearbox is correct.
2.
Delay time when the direction-of-rotation is suddenly changed. This prevents that it continues in
the initial direction.
3.
Stops automatically when the safety switch is operated. Manual or automatic control in the
opposite direction-of-rotation stays possible.
4.
Error-message indication with four LEDs on the control board (A2).
5.
Feedback of error messages with a fault contact.
7. COMMISSIONING INSTRUCTIONS
The commissioning is only permitted to approved personnel.
7.1 Commissioning - Conditions and starting points
Refer to the “Installation Manual” 265342 and the “User Manual” 265343 of the SynCore system.
Refer to the “Product Manual” of the used Ridder motor gearbox and the “User Manual” 265343 (of
the SynCore system) at
adjust
the
end positions!
Do not go across the limits of the system. This prevents damage or
injury.
Before the system is put into operation, the installer must always
make sure that the limit switch is correctly adjusted.
Make sure that there is no blockage of the system before the limit-
switch system is adjusted. This prevents damage or injury.
Ridder Drive Systems B.V.