47
current value, over voltage protection value, over
current protection value into the corresponding data
group(as shown in figure 2).
then press
to confirm, it will show
at
bottom left, you can press
button and choose “X”,
then press ENTER to cancel, after change the setting
value it will show
.
Press
+ keypad button 1-9 to quick call out the saved data (as shown
above in figure 3) from the corresponding data group. Press
to confirm, It will
show
,
after change the setting value it will show
. When
disable the “Take OK” option, it will be called out
directly to change the data setting value, no prompt.
is the default data group, when you edit the
settings and press
button or rotate encoder
potentiometer to change the setting and press
encoder potentiometer to return, it will be stored into
automatically, or you go
to the data group setting menu, change the setting and press encoder potentiometer
to return, it will save too, and it will not save by other settings.
1.4.2.4
Keypad lock and unlock
Keypad lock operation video
:
https://drive.google.com/drive/folders/121yIfNLh3O99AU4tUkxtC5q34XT3s
nn1?usp=sharing
Press
+
to lock or unlock the keyboard.
And the keypad will be automatically locked when
communication starts, there will be
displayed on
the top (cannot unlock manually), at this time, the
power button can be used, pressing other button will
show(as shown in figure 4), the keypad will be automatically unlocked after 3
seconds when the connection disconnected, there will be
displayed.
figure 2
figure 3
figure 4