声明:本说明书著作权归杭州睿登科技有限公司所有,未经允许任何单位或个人不得用于商业用途。
49
automatically
decrease the output current setting value. When used together with low power
power source, it is recommended to set the value as
the rated power of the power source*95%;
Temperature
unit is
℃
by default, it can be
switched between
℃
and
℉
(figure 6);
Battery Charger Sub-menu(figure 7):
CutOff Current
is set to 10mA by default and it can
be edited. On the top you can see the *1 icon, it is the
adjustment magnification, you can press
or
to choose the different
magnification so that you can set
the value quickly, when the real output current is
lower than this set value, the output will be cut off
automatically.
Cut-Off Temp.
is set to 60
℃
by default, when the
external temperature sensor detect over 60
℃
, the
output will be cut off automatically.
Communication Sub-menu(figure 8):
Interface
is set to USB by default, you can also set
it to WIFI/TTL/RS485, USB means the micro USB port,
you can see
on the top when set it USB, and
when the communication starts, it will show
; You
need to insert a WIFI board to use the WIFI function,
and it will show
on the top, and when the
communication starts, it will show
; TTL is not
available now; You need to insert RS485 module to use
RS485, and it will show
on the top, and when the
communication starts, it will show
.
Address
is set to 001 by default, you can set it between 001 and 255;
The Baud rate and address on the device should be same with the information
on PC software or APP. You can see more communication at PC software and APP
section.
Date and Time Sub-Menu(figure 9):
Date
and
Time
can be set from Year 2000 to 2100, press
or
you can
select the option, and use encoder potentiometer can adjust the value, it will be
applied immediately when you change the value, please do not set the wrong time.