Model KT-190 and KT-200 Pipe Thawing Units

Ridge Tool Company

7

4. Keep clamps dry and clean.

Tool Storage

Electrical equipment must be kept indoors

or well covered in rainy weather. Store the tool in a locked
area that is out of reach of children and people unfamiliar
with Pipe Thawing tools. This tool can cause serious injury
in the hands of untrained users.

Service and Repair

WARNING

Service and repair work on this tool must be performed by
qualified repair personnel. Thawing unit should be taken to
a RIDGID Independent Authorized Service Center or re-
turned to the factory. All repairs made by Ridge service
facilities are warranted against defects in material and
workmanship.

When servicing this tool, only identical replacement parts
should be used. Failure to follow these instructions may
create a risk of electrical shock or other serious injury.

If you have any questions regarding the service or repair
of this machine, call or write to:

Ridge Tool Company
Technical Service Department
400 Clark Street
Elyria, Ohio 44035-6001
Tel: (800) 519-3456
E-mail: TechServices@ridgid.com

For name and address of your nearest Independent
Authorized Service Center, contact the Ridge Tool Com-
pany at (800) 519-3456 or http://www.ridgid.com

2. Place one clamp on each side of the frozen section of

pipe. Open the faucet where no water flows.

Making pipe connections before plugging

in unit prevents arcing between clamps and pipe.

3. Plug unit into a grounded 15 amp outlet making sure

to position the power cord along the clear path se-
lected earlier.

4. Move switch to ON (UP position on KT-190. Center

switch down to low position, left switch to A on KT-
200).

5. If current is below 15 amps on KT-200, switch to B. If

current is still below 15 amps, switch to high position
on center switch and right switch up to C.

6. Continue until 15 amps is reached but not exceeded,

D switch setting is used with long runs.

Thawing time may vary from a few seconds to several
hours depending on length and diameter of pipe being
thawed. If time seems unreasonable, check clamps for
proper placement.

NOTE! This tool is equipped with a thermal overload for

added safety. If thawing for long periods of time at
maximum current, the unit may shut down auto-
matically. Unit will resume operations auto-
matically after approximately 3 minutes.

Tool Removal

1. When water lines have thawed, turn switch to the

OFF position and unplug power cord from the elec-
trical outlet.

2. Remove clamps from the pipe.

Clamp tips are hot and can cause burns.

3. Allow clamps to cool before coiling cables and placing

the unit in storage. While the clamps are hot, keep
them away from combustible materials or articles
that can be damaged by heat.

Maintenance Instructions

WARNING

Make sure unit is unplugged from power source be-
fore performing maintenance or repairs.

Tool Maintenance

1. Replace damaged, frayed, broken or worn cables.

2. Periodically clean lugs with steel wool and emery

cloth.

3. Replace damaged, frayed, broken or worn machine

cord.

WARNING

WARNING

WARNING

Summary of Contents for KT-190

Page 1: ...TOR S MANUAL Français 9 KT 190 KT 200 WARNING Read this Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electri cal shock fire and or serious personal injury ...

Page 2: ...tions Description 3 Specifications 3 Standard Equipment 4 Accessories 4 Cables and Clamps 4 Problem Diagnostics Main Service Lines 4 Tap Water Lines 4 Tool Assembly 5 Tool Inspection 5 Tool Set Up 5 Operating Instructions Thawing Tap Water Lines 6 Tool Removal 7 Maintenance Instructions 7 Tool Storage 7 Service and Repair 7 Electrical Schematics 8 Lifetime Warranty Back Cover Ridge Tool Company ii...

Page 3: ...KT 190 and KT 200 Pipe Thawing Units Record Serial Number below and retain product serial number which is located on nameplate Serial No KT 190 and KT 200 Pipe Thawing Units ...

Page 4: ...ords are rated for outdoor use and reduce the risk of electrical shock Use only three wire extension cords which have three prong grounding plugs and three pole re ceptacles which accept the tools plug Use of other extension cords will not ground the tool and increases the risk of electrical shock Use proper extension cords See chart Insufficient conductor size will cause excessive voltage drop lo...

Page 5: ...f injury or fire Do not touch the clamp tips or cable connections Reduces the risk of burns Do not operate unit with housing removed Exposure to internal parts may result in injury Make both pipe connections before plugging in unit Prevents electrical arcing between the clamps and the pipe Use cable and clamps provided with unit Incorrect cables may result in overheating of the wires Keep clamps a...

Page 6: ...zen line by opening faucets and checking for water flow The frozen section will normally be in an out side wall or in a crawl space with poor insulation If one faucet does not have running water and the next faucet does frozen section is between faucets Place clamps on either hot or cold water lines not on faucets Refer to Thawing Tap Water Lines for procedure KT 190 KT 200 Output 6 0 Volts 4 5 7 ...

Page 7: ... leads are securely fastened to thawing unit If cable or clamps are damaged do not use the Thawing Tool until they are replaced Only use cable and clamps provided with the unit 4 Clean any oil grease or dirt from handles controls and clamps 5 Inspect the Thawing Tool for any broken or missing parts as well as damage to the metal enclosure If any of these conditions are present do not use the Thaw ...

Page 8: ...arby objects to ignite To reduce risk of electrical shock keep all electrical connections dry and off the ground Do not touch plug with wet hands Operating Instructions WARNING To reduce risk of electrical shock keep all electri cal connections dry and off the ground Do not touch plug with wet hands Be very careful when thawing frozen pipes Clamp tips and cable connections become hot during use Av...

Page 9: ...en clamps and pipe 3 Plug unit into a grounded 15 amp outlet making sure to position the power cord along the clear path se lected earlier 4 Move switch to ON UP position on KT 190 Center switch down to low position left switch to A on KT 200 5 If current is below 15 amps on KT 200 switch to B If current is still below 15 amps switch to high position on center switch and right switch up to C 6 Con...

Page 10: ...Model KT 190 and KT 200 Pipe Thawing Units Ridge Tool Company 8 Electrical Schematics KT 190 Thawer 115V 60Hz OUTPUT TERMINALS KT 200 Thawer 115V 60Hz OUTPUT TERMINALS ...

Page 11: ...ongélation des canalisations KT 190 et KT 200 Appareils de décongélation des canalisations KT 190 et KT 200 Inscrivez ci dessous le numéro de série de la plaque signalétique l appareil pour future référence N de série ...

Page 12: ...iption 13 Spécifications 13 Équipements de base 13 Accessoires 13 Câbles et pinces 13 Diagnostique des anomalies Réseau d alimentation général 14 Conduites individuelles 14 Montage de l appareil 14 Inspection de l appareil 15 Préparation de l appareil 15 Fonctionnement de l appareil Décongélations de conduites d eau de ville 16 Replis du matériel 17 Entretien 17 Stockage de l appareil 17 Service a...

Page 13: ...ique ni tirer sur celui ci pour débrancher l ap pareil Gardez le cordon à l abri des sources de chaleur de l huile des angles tranchants et des pièces mobiles Remplacez immédiatement tout cordon endommagé Les cordons endommagés aug mentent les risques de choc électrique Lorsque vous utilisez l appareil à l extérieur utilisez une rallonge électrique portant la désignation W A ou W Ce type de rallon...

Page 14: ...aration ou l entretien de l appareil par du personnel non qualifié peut entraîner des blessures Lors de la réparation de l appareil utilisez exclu sivement des pièces de rechange identiques à celles d origine Suivez les instructions de la sec tion Entretien du mode d emploi L utilisation de pièces de rechange non homologuées et le non respect des consignes d entretien peut créer un risque de choc ...

Page 15: ...ils de décongélation des canalisations RIDGID sont prévus pour le traitement des canalisations en acier fonte ou cuivre de 1 2 à 11 2 pouce de diamètre et d une longueur maximale de 150 pieds KT 200 Les deux ap pareils KT 190 et KT 200 font appel à un courant basse tension à haute intensité pour rapidement dégeler les conduites d eau bloquées par la glace Grâce à cette méthode il n est pas nécessa...

Page 16: ...se trouve entre les deux robinets Placez les pinces sur les conduites d eau chaude ou d eau froide mais pas sur les robinets eux mêmes Reportez vous à la section Décongélation des conduites de distribution pour la méthode à suivre Assemblage de l appareil MISE EN GARDE L appareil doit être correctement assemblé afin d éviter les risques d accident Respectez la méth ode suivante Figure 3 Appareil d...

Page 17: ... endroit au sec pour l appareil et son utilisateur Ne pas utiliser cet appareil lorsque vous avez les pieds dans l eau Ne renferme pas de liquides vapeurs ou pous sières combustibles qui risqueraient de s enflammer 2 Positionnez l appareil de décongélation KT 190 ou KT 200 à proximité de l endroit où la canalisation est soupçonnée d être gelé 3 Assurez vous que l appareil est débranché et éteint i...

Page 18: ...pareil est équipé d un disjoncteur de sécu rité thermique Lorsque l appareil fonctionne au courant maximum pendant de longues périodes il risque de s arrêter automatiquement L appareil se remettra en marche automatiquement au bout d environ 3 minutes Maintenez toutes les connexions électriques au sec et surélevées afin de limiter les risques de choc électrique Ne touchez pas la fiche avec des main...

Page 19: ...appareil dans un endroit sous clé et hors de la portée des enfants et des amateurs Cet appareil de décongélation risque de provoquer de graves blessures s il tombe entre les mains d utilisateurs non initiés Ridge Tool Company 17 Service après vente et réparations MISE EN GARDE La révision et la réparation de cet appareil doivent être confiées à un réparateur qualifié L appareil de décon gélation d...

Page 20: ...émas électriques Appareil de décongélation KT 190 115V 60 Hz Bornes de sortie Appareil de décongélation KT 200 115V 60 Hz Bornes de sortie Noir Blanc Masse Marche Arrêt Disjoncteur thermique 115 V 25 à 50 Hz 15 A Noir Blanc Masse Ampèremètre Interrupteur marche arrêt Disjoncteur thermique ...

Page 21: ...Ridge Tool Company 19 Appareils de décongélation des canalisations KT 190 et KT 200 ...

Page 22: ...Ridge Tool Company 20 Appareils de décongélation des canalisations KT 190 et KT 200 ...

Page 23: ...Workmanship FULL LIFETIME WARRANTY Ce qui est couvert Les outils RIDGE sont garantis contre tous vices de matériaux et de main d oeuvre Durée de couverture Cette garantie est applicable durant la vie entière de l outil RIDGE La couverture cesse dès lors que le produit devient inutilisable pour raisons autres que des vices de matériaux ou de main d oeuvre Pour invoquer la garantie Pour toutes répar...

Reviews: