Operating Instructions and Parts Manual

4

PRE-INSTALLATION (CONT'D)

TANKS - CONVENTIONAL STORAGE

The function of the tank is to store a quantity of water under 

pressure. When full, the tank contains approximately 2/3 water 

and 1/3 compressed air. Then compressed air forces the water 

out of the tank when a faucet is opened. An air volume control 

automatically replaces air lost or absorbed into the water. The 

usable water, or drawdown capacity, of the tank is approximately 

1/6 of the tanks total volume when operated on a 30/50 pressure 

setting (Figure 1).

TANKS - PRECHARGED STORAGE

A precharged storage tank has a flexible bladder or diaphragm 

that acts as a barrier between the compressed air and water. This 

barrier prevents the air from being absorbed into the water and 

allows the water to be acted on by compressed air at initially higher 

than atmospheric pressures (precharged). More usable water is 

provided than with a conventional type tank. Precharged tanks are 

specified in terms of a conventional tank. For example, a 20 gallon 

precharged tank will have the same usable water or drawdown 

capacity as a 40 gallon conventional tank, but the tank is smaller in 

size (Figure 1).

AIR VOLUME 

CONTROL

Figure 1 - Conventional & Precharged Storage Tanks

BLADDER

PRECHARGED TANK

CONVENTIONAL TANK

INSTALLATION

LOCATION

Select a location as close to the water supply as possible. Be sure 

to comply with any state or local codes regarding the placement 

of the pump. The equipment must be protected from the elements 

or voids warranty. A basement or heated pump house is a 

good location. Make sure the pump has proper ventilation. The 

temperature surrounding the pump is not to exceed 100° F (38°C) 

or nuisance tripping of the motor overload may occur.

WELLS

A new well should be pumped clear of sand before installing the 

pump. Sand will damage the pumping parts and seal. The draw-

down level of the well should not exceed the maximum rated depth 

for the pump. The capacity of the pump will be reduced and a loss 

of prime may occur.

PIPING

Inlet piping may be copper, steel, or rigid PVC plastic.

   Flexible pipe is prohibited on suction pipe  

(inlet pipe).

 MISE EN GARDE

   Un tuyau flexible est interdit sur le tuyau 

d'aspiration (tuyau d'entrée).

The pipe must be clean and free of rust or scale. Use a pipe joint 

compound on the male threads of the metal pipe. Plumber’s seal 

tape should be used with plastic threads. All connections must be 

air tight to insure normal operation.
Slope all inlet piping upwards towards the pump to prevent 

trapping air. Unions or hose couplings can be installed near pump 

to facilitate removal for servicing or storage. A rubber hose installed 

between the water system and the house piping will reduce the 

noise transmitted to the house.

PRESSURE SWITCH

The pressure switch provides for automatic operation.  

The pump starts when pressure drops to a cut-in setting. The 

pump stops when pressure reaches a cut-out setting.  

The pressure switch is preset and is 

NOT

 adjustable.

PIPE SIZES

Long horizontal pipe runs and an abundance of fittings and 

couplers decrease water pressure due to friction loss. See Chart 2 

below to determine the proper pipe size.

CHART 2 - PIPE SIZING

Pump Model

Pump Opening

0-25

26-100

100-300

Shallow Well

Inlet

1-1/4 in.

1-1/2 in.

2 in.

SHALLOW WELL INSTALLATION

A shallow well pump can be used when the pump is located less 

than 25 feet vertically of the water level. Shallow well pumps have 

only one pipe between the pump and the water supply (Figure 2).

DRILLED WELL (FIGURE 12 ON PAGE 11)

1.   Install a foot valve on the first section of pipe (Figure 2, 

Illustration A).

2.   Lower the pipe into the well.
3.   Add pipe until the foot valve is 5 feet below the lowest 

anticipated water level.

FOOT VALVE

WELL CASING

TO PUMP

WELL SEAL

Figure 2 

Figure 2 
Illustration A

Illustration A

Summary of Contents for RSWS Series

Page 1: ...del HP PSI Discharge Head Lift Distance 0 ft 5 ft 10 ft 15 ft 20 ft 25 ft RSWS75 3 4 30 779 750 721 691 662 633 40 644 615 586 557 528 499 50 510 481 451 422 393 364 RSWS50 1 2 30 711 674 638 601 565 529 40 543 506 470 433 397 361 50 375 338 302 265 229 193 Intended for Indoor Use Only Please read and save these instructions Read carefully before attempting to assemble install operate or maintain ...

Page 2: ...ESCRIPTION Shallow well jet pumps are single stage residential water pumps designed for pumping potable water in applications where the water is located less than 25 feet vertically from the pump A pressure switch is a standard feature The shallow well pump must be mounted to either a pre charged conventional type or free standing pressure tank Intended for indoor use only Installation of this pum...

Page 3: ...cal circuit checked by a licensed or certified electrician to make sure the circuit is properly grounded 12 The circuit voltage and frequency of electrical current must correspond with the specifications of the motor 13 Do NOT attempt repairs to the electric motor All repairs to the motor must be completed by a licensed electrician Do NOT touch an operating motor Modern motors are designed to oper...

Page 4: ...lling the pump Sand will damage the pumping parts and seal The draw down level of the well should not exceed the maximum rated depth for the pump The capacity of the pump will be reduced and a loss of prime may occur PIPING Inlet piping may be copper steel or rigid PVC plastic Flexible pipe is prohibited on suction pipe inlet pipe MISE EN GARDE Un tuyau flexible est interdit sur le tuyau d aspirat...

Page 5: ... well or sand or sediment WILL be drawn into the system MISE EN GARDE Le clapet de pied DOIT au moins être à 45 7 cm 18 po du fond du puits sinon du sable ou des sédiments POURRAIENT être aspirés dans le système NOTE When a lake is used as a water supply make sure the inlet pipe is deep enough to be submerged at all times Slope the horizontal piping upward toward the pump to prevent trapping air T...

Page 6: ...ire directly to the metal well casing or use a ground electrode furnished by the power company There is only one proper ground terminal on the unit The terminal s is located under the pressure switch cover is painted green and is identified as GRD The ground connection must be made at this terminal Figure 5 The ground conductor must not be smaller than the circuit conductors supplying the motor Di...

Page 7: ...tank with the correct air to water ratio for the system to operate If the air volume control is good the pump will shut off at the desired cut off and will be adjusted correctly WATERLOGGED TANKS PRECHARGED If a precharged tank becomes waterlogged the bladder is normally leaking or broken 1 Test the tank by depressing the air valve The air valve will expel water if the bladder is broken 2 If broke...

Page 8: ...ard washer 2 Carefully slip seal plate over shaft Do not disturb seal position in seal plate The seal plate must be orientated during assembly so the two screw holes are on a horizontal line across the motor shaft Figure 10 This placement should be done to ensure proper draining and priming 3 Place rotating shaft seal member in position on impeller and press into place Take care not to press again...

Page 9: ...th new parts in reverse order 14 Wipe down the seal plate to remove any debris or loose rust 15 Push the ceramic seat of the shaft seal into the seal plate using the cardboard ring provided to keep the ceramic face clean You can use a little water or dish soap to lubricate the seal pocket to make assembly easier 16 Slide the square cut gasket over the flange on the seal plate make sure not to let ...

Page 10: ...alve may be clogged or stuck closed 8 Pump not fully primed 9 Water level below maximum lift specification 10 Undersized piping 11 Gaseous well 12 Distorted venturi 13 Incorrect jet for application 14 Undersized pump 15 Pump cavitates sounds like pumping gravel 16 Low supply voltage 1 Lower suction pipe further into wall 2 Open faucet to allow air to vent while priming pump 3 Repair or replace to ...

Page 11: ... or concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DRILLED WELL A hole bored into the earth with machinery and lined with pipe Depths range from a few feet to over 1000 feet Common well diameters are 2 3 4 and 6 for domestic water wells F CISTERN An und...

Page 12: ...IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY WAY ...

Reviews: