GENERAL
11
L
power 230V
X1
-01-
1
N
power 230V
X1
-01-
2
PE
X1
-01-
3
Control L
X1
-02-
1
Control
N
X1
-02-
2
Fan power L
X2
-01-
1
Fan power N
X2
-01-
2
pi 1 L
X2
-02-
1
pi 1
N
X2
-02-
2
Lockout L
X2
-03-
1
N
X2
-03-
2
L-
Vm
ix
X2
-04-
1
Common
X2
-04-
2
L-
PB
X2
-04-
3
ER
X2
-05-
1
Si
c
X3
-01-
1
Si
c
X3
-01-
2
VG
230V
RC
X3
-02-
1
VG
230V
RC
X3
-02-
2
T-at
N
X3
-03-
1
T-at L
X3
-03-
2
0
M
X3
-04-
1
GND
Fan cont
ro
l
X1
4-
1
+U
B
Fan cont
ro
l
X1
4-
2
HA
LL F
an cont
ro
l
X1
4-
3
PW
M
Fan cont
ro
l
X1
4-
4
+ 26
V
X1
1-
1
Si
c1
X1
1-
2
Si
c2
X1
1-
3
X1
1-
4
X1
1-
5
VD
C
X1
1-
6
IN
X1
1-
7
AN4 Flue gas temp. sensor
X1
1-
8
AN
3
BW
1
X1
1-
9
AN
2 SR
X1
1-
10
AN
1 SM
X1
1-
11
+5
V
X1
1-
12
AN
5 +5
V
SE
X1
0-
06-
2
AN
5
-I-S
E
X1
0-
06-
1
AN
3 +5
V
SB
X1
0-
05-
2
AN
3
I SB
X1
0-
05-
1
Pa
X1
0-
04-
2
Pa
X1
0-
04-
1
Si
c-
X1
0-
03-
2
Si
c-
X1
0-
03-
1
TA
1
X1
0-
02-
2
TA
1
X1
0-
02-
1
TA
2-
S
QAA7
3
X1
0-
01-
2
TA
2-
GND
QAA7
3
X1
0-
01-
1
AGU2.5
X50-5
AGU2.3
X30-14
OCI420
X40-5
X30-1/14
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
L1 N PE
1
2
AT
PE
Fan-PWM
L1 N PE
RIV
L1
1
L
2
N1
3
N
4
PE
5
FILTRO
6.3A
C1
-L
3
C1
-N
C1
-P
E
C1
-L
1
C1
-L
2
M9 M8
M7 M6 M5 M4
M20
M21
M10
M11
M
+
1
TA
C
2
PE
3
DCV
PV
M
4
-
5
L1
N
PE
M1 M2 M3
FI
FU
Connections to be made
by the installer
IG
PB
PI
Sb
TF
Pboiler
Pgas
Sm
SE
SCH2
SCH1
(*)
VE1
H2
TS
Treg
A
B
C
D
E
F
G
TR1
ER
EA
Sr
Sf
L1
L2
PE
N
L3
L1
L2
PE
N
L3
PE
N
L3
TA
230 Vac
VG1
230V~50Hz
C
A
B
D
E
F
G
open
Y1
clos
e
Y2
BSB
-4
p
BS
B
NA
/0-10V
H1
CH1pump
Q2
QX
1
QX
1
St.cyl.pum
p
Q3
1st stage
L1
PE
PE
T1
T1
N
N
T2
T2
X3
0-10
p
X3
0
L1
L1
S3
S3
N
N
CH1 snsr
BX
1
BX
1
ground
M
Boiler snsr
B2
DHW 1 snsr
B3
Outdoor snsr
B9
ground
BX
2
BX
2
LPB-
4p
LP
B
ground
M
X50-5p
X5
0
X60-6p
X6
0
LP
B
DB
ground
MB
L
L
PE
PE
S3
S3
4
4
SK
2
SK
2
SK
1
SK
1
N
N
N
N
N
N
N
N
PE
PE
PE
PE
PE
PE
PE
PE
M
M
M
M
M
M
M
M
CL
+
CL
+
CL
+
CL
+
CL
-
CL
-
CL
-
CL
-
G+
G+
SCH3
SCH4
DB-LPB
MB-LPB
LMU
CLIP-IN
communication card
L
230
V
N
230V
L
P1
N P1 C
va
l
C
co
mu
n.
A
va
l
NTC/10K
NTC 10K
SCH5
PI1
VM1
SI1
B1 M
Fan-PWM
Connection schematic for added accessories
SCH3 RVS control card (**)
SCH4 Room unit control card
SCH5 Mixed zone interface card (clip-in)
Pl1
Additional mixed zone pump
VM1 Mixer valve for additional zone
SI1
CH flow temperature sensor for additional mixed zone
(**)
Refer to the instructions provided with your card for details on how to connect it to the RVS unit.