TECHNICAL ASSISTANCE SERVICE
68
Correct positioning of the ignition electrode and flame de-
tection sensor is essential for efficient ignition and combus-
tion.
With the burner removed, verify the state of wear and the po-
sitioning of the ignition electrode and flame detection sensor
according to the figure below. Replace if damaged or worn.
POSITIONING THE ELECTRODES
- Remove the front panel from the boiler and locate the
condensate drain siphon (1).
- Remove the split pin (2), detach the corrugated con-
densate drain hose, and remove the siphon. Unscrew
the two caps (3) to disassemble the siphon.
- Remove the float (4) and clean all internal components.
On completion of cleaning, follow the above steps in the
reverse order to refit all removed parts.
2
1
3
3
4
CLEANING THE CONDENSATE DRAIN AND SIPHON
b
It is essential to respect the dimensions in the figure.
8.2
4.0
16.3