20013748
4
GB
ELECTRICAL WIRING
Brown
Wh
ite (5
0V)
Blue
Motor
Capacitor
Regulating thermostat
Neutral
Switch with fuse
6A
max.
N
L
M
~
S7026
Black
NOTES
– Wires of 1 mm
2
section.
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
– To remove the control-box from the burner,
loosen screw (A)
(see figure)
and pull towards
the arrow.
– The photoresistance is fitted directly into the con-
trol-box
(underneath the ignition-transformer)
on
a plug-in support.
TESTING
Check the shut-down of the burner by opening the
thermostats.
ATTENTION
Do not connect burner’s grounding, to failure
indicator terminal
. This may result the destroy
of the control box.
WARNING
Do not exchange the neutral with the phase.
230V
~
50Hz
N
L
Limit thermostat
with manual resetting
Remote lock-out lamp
(230V - 0.5A max.), if required
1
2
3
4
5
6
7
8
9
Blue
Brown
Terminal block of
control-box
530SE
*
Valve
T
T
RUN OF THE ELECTRICAL CABLE
1
- Grommet
N
- Neutral
2
- Cable-clamp
L
- Phase
3
- Terminal block
- Burner-earth
A
3
2
1
D5228
Black
CA
RRIED-OUT B
Y THE
INSTALLER
CA
RRIED-OUT IN THE
FA
CTOR
Y