GENERAL
19
Setting the room temperature setpoint
Turn the knob (14) to set the desired
room temperature
comfort setpoint .
Proceed in a similar way to set the
room temperature redu-
ced setpoint .
- Press the "
OK
" button (13).
- Select “Heating circuit 1”.
- Set the room temperature reduced setpoint.
b
After changing a setpoint, you need to wait about 2
hours for the new setting to have any effect on room
temperature.
b
If no room unit is installed, changing the room tempera-
ture setpoint simply shifts the heating curve.
14
13
6
Comfort setpoint
Information
i
Press the information button (6) to display:
- Errors or maintenance codes (see the “Errors/Maintenance codes” section).
- Special messages.
Other screens:
b
Other screens depend on the system configuration and status . Some of the info lines shown below may not
therefore appear .
Chimney sweep mode
R
When you select manual mode, the "
h
" symbol appears
and relays are energised/de-energised not according to
any heating program but according to a default manual
setting that can be set by pressing the information button
(6).
Chimney sweep mode
p
To select chimney sweep mode, press the chimney
sweep button (11) briefly (max. 3 seconds). The "
h
"
symbol is displayed. Chimney sweep mode prepares the
boiler for combustion analysis. To exit chimney sweep
mode, press the button (11) again. The system exits
chimney sweep mode automatically after 1 hour.
12 11 6
Boiler temperature
- Room temperature
- Minimum room temperature
- Maximum room temperature
- Room 1 setpoint
- Room 2 setpoint
- Room 3 setpoint
- Cascade flow temperature
- Boiler temperature
- Outside temperature
- Minimum outside temperature
- Maximum outside temperature
- DHW 1 temperature
- DHW 2 temperature
- Buffer tank 1 temperature
- Buffer tank 2 temperature
- Buffer tank temperature setpoint
- Flow 1 temperature
- Flow 1 temperature setpoint
- Flow 2 temperature
- Flow 2 temperature setpoint
- Flow 3 temperature
- Flow 3 temperature setpoint
- Collector 1 temperature
- Wood fuelled boiler temperature
- Solar flow temperature
- Solar return temperature
- 24 hours solar energy yield
- Total solar energy yield
- Pool temperature
- Pool setpoint
- Heating circuit 1 status
- Heating circuit 2 status (not active)
- Heating circuit 3 status
- Cooling circuit state
- DHW status
- Boiler status
- Solar heating status
- Solid fuel boiler status
- Buffer storage tank status
- Pool state
- Error message
- Maintenance message
- Floor curing function
- Date and time
- Telephone number of technical assi-
stance centre