TECHNICAL ASSISTANCE SERVICE
54
1
3
2
4
4
REMOVING THE BURNER CONTROL BOX
Proceed as follows to remove the burner control box:
- Remove coil (1) and connections.
- Loosen the screws (2), open the protection (3) and
remove all components.
- Loosen the two screws (4), slightly move the control box
and disconnect the wires from the electrodes.
The burner must be shut down and power and fuel
disconnected before the control box is removed .
BURNER ELECTRICAL CONNECTIONS
L1
N T1 T2 S3 B4
1 2
L1
N T1 T2 S3 B4
RESET
MO535-MRSFUI
Burner
ground
CONTROL BOX
Capacitor
Motor
Heating element
Black
White
Blue
Flame
detector
Burner lockout indicator
(on boiler control panel)
7 pin connector
2 pin connector
Fuel
shut-off
cock
Remote burner reset button
(on boiler control panel)
Ignition
electrodes
Start
enable
thermostat
after pre-heating