background image

5

ENGLISH

THERMOSTATIC DHW RECIRCULATION KIT

DESCRIPTION

This thermostatic recirculation kit for DHW mixers is supplied separately from the mixer itself. The kit consists of a pump 

with a non-return valve and shut-off cock, pipe, seals and a safety valve. 

CONTENTS OF KIT

Description   

Qty

- Recirculation pump with packing  

1

- Instruction manual  

1

GENERAL SAFETY INFORMATION AND PRECAUTIONS

READ THE MANUAL SUPPLIED WITH THE DHW MIXER THOROUGHLY BEFORE PERFORMING ANY WORK ON IT.

MAIN COMPONENTS

Pump

Pipe with seals

Safety valve

TECHNICAL SPECIFICATIONS

Flow rate  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 m

3

/h

Head  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 m

Pumped water temperature . . . . . . . . . . . . . . . . .2 ÷ 65 °C

Maximum pressure. . . . . . . . . . . . . . . . . . . . . . . .10 bar

Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .200-240 V

Frequency  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50-60 Hz

Index of protection   . . . . . . . . . . . . . . . . . . . . . . .IP 44

1

2

3

Summary of Contents for 20083502

Page 1: ...FEZIONE Descrizione Q t KIT di ricircolo con imballo 1 Foglio di istruzioni 1 AVVERTENZE GENERALI E REGOLE FONDAMENTALI DI SICUREZZA CONSULTARE ATTENTAMENTE IL MANUALE A CORREDO DEL MODULO SANITARIO P...

Page 2: ...RISTICHE CIRCOLATORE DIMENSIONI E PESI A 75 mm B 142 mm C 112 mm DN 15 Peso 1 3 kg H m P W 0 0 2 0 4 0 6 0 8 1 0 1 2 0 100 200 300 400 500 Q l h 6 6 6 8 7 7 2 7 4 7 6 7 8 8 8 2 110 G 1 1 4 G 1 1 4 G 1...

Page 3: ...ne alla morsettiera del circolatore Svitare la vite sul coperchio della pompa Rimuovere il coperchio Inserire il cavo facendolo passare attraverso il pressa cavo Effettuare il collegamento nella morse...

Page 4: ...rcassa del motore La pompa si spegne automaticamente quando la temperatura dell acqua raggiunge il valore desiderato La temperatura pu essere impostata tra 20 C e 70 C attraverso il selettore posto su...

Page 5: ...ONTENTS OF KIT Description Qty Recirculation pump with packing 1 Instruction manual 1 GENERAL SAFETY INFORMATION AND PRECAUTIONS READ THE MANUAL SUPPLIED WITH THE DHW MIXER THOROUGHLY BEFORE PERFORMIN...

Page 6: ...CURVES FOR PUMP DIMENSIONS AND WEIGHTS A 75 mm B 142 mm C 112 mm DN 15 Weight 1 3 kg H m P W 0 0 2 0 4 0 6 0 8 1 0 1 2 0 100 200 300 400 500 Q l h 6 6 6 8 7 7 2 7 4 7 6 7 8 8 8 2 110 G 1 1 4 G 1 1 4 G...

Page 7: ...confor mity to applicable standards Proceed as follows to connect the power cable to the pump s power terminals Unscrew the pump cover retaining screw Remove the pump cover Insert the cable through t...

Page 8: ...itches off automatically if the temperature of the water reaches the setpoint The thermostat on the pump body allows you to set any temperature between 20 C and 70 C MAINTENANCE DISASSEMBLY b b All wo...

Reviews: