background image

7

ENGLISH

CONNECTING THE RECIRCULATION KIT

 

b

Live electrical equipment!

Proceed as follows to connect up the thermostatic DHW 

mixer recirculation accessory. 

Shut off the water flow by closing the cold water inlet 

ball valve (1) and the hot water outlet ball valve (2).

Remove the 1” F plug (3) from the DHW mixer.

Install the recirculation accessory and tighten the wa-

tertight fitting.

Connect the recirculation pump to a 230 Vac 50-60 Hz 

power supply.

ELECTRICAL CONNECTIONS

The accessory must be installed and all electrical con-

nections made by suitably qualified personnel in confor-

mity to applicable standards.

Proceed as follows to connect the power cable to the 

pump’s power terminals.

 - Unscrew the pump cover retaining screw.

 - Remove the pump cover.

 - Insert the cable through the cable guide.

 - Connect the wires to the terminals.

 - Fit the pump cover.

 - Tighten the pump cover retaining screw.

Connect the pump’s power cable to a fused, two-pole 

switch (power supply 230 VAC, 50-60 Hz).

The system must be correctly connected to ground.

 

b

The controller must be connected to the mains po-

wer supply via an earth leakage breaker in accor-

dance with applicable standards. Correct functio-

ning is only guaranteed provided the controller is 

used with the pump for which it is designed. The 

manufacturer cannot be held responsible for the 

consequences of improper uses. 

1

2

3

Summary of Contents for 20083502

Page 1: ...FEZIONE Descrizione Q t KIT di ricircolo con imballo 1 Foglio di istruzioni 1 AVVERTENZE GENERALI E REGOLE FONDAMENTALI DI SICUREZZA CONSULTARE ATTENTAMENTE IL MANUALE A CORREDO DEL MODULO SANITARIO P...

Page 2: ...RISTICHE CIRCOLATORE DIMENSIONI E PESI A 75 mm B 142 mm C 112 mm DN 15 Peso 1 3 kg H m P W 0 0 2 0 4 0 6 0 8 1 0 1 2 0 100 200 300 400 500 Q l h 6 6 6 8 7 7 2 7 4 7 6 7 8 8 8 2 110 G 1 1 4 G 1 1 4 G 1...

Page 3: ...ne alla morsettiera del circolatore Svitare la vite sul coperchio della pompa Rimuovere il coperchio Inserire il cavo facendolo passare attraverso il pressa cavo Effettuare il collegamento nella morse...

Page 4: ...rcassa del motore La pompa si spegne automaticamente quando la temperatura dell acqua raggiunge il valore desiderato La temperatura pu essere impostata tra 20 C e 70 C attraverso il selettore posto su...

Page 5: ...ONTENTS OF KIT Description Qty Recirculation pump with packing 1 Instruction manual 1 GENERAL SAFETY INFORMATION AND PRECAUTIONS READ THE MANUAL SUPPLIED WITH THE DHW MIXER THOROUGHLY BEFORE PERFORMIN...

Page 6: ...CURVES FOR PUMP DIMENSIONS AND WEIGHTS A 75 mm B 142 mm C 112 mm DN 15 Weight 1 3 kg H m P W 0 0 2 0 4 0 6 0 8 1 0 1 2 0 100 200 300 400 500 Q l h 6 6 6 8 7 7 2 7 4 7 6 7 8 8 8 2 110 G 1 1 4 G 1 1 4 G...

Page 7: ...confor mity to applicable standards Proceed as follows to connect the power cable to the pump s power terminals Unscrew the pump cover retaining screw Remove the pump cover Insert the cable through t...

Page 8: ...itches off automatically if the temperature of the water reaches the setpoint The thermostat on the pump body allows you to set any temperature between 20 C and 70 C MAINTENANCE DISASSEMBLY b b All wo...

Reviews: