10
TECHNICAL DATA
(1) Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m s.l.m.
(2) Pressure at test point 7)(A)p.12, with zero pressure in the combustion chambre, an maximum burner output.
(3) Sound pressure measured in manufacturer’s combustion laboratory, with burner operating on test boiler and at maximum rated output, and measured from a dis-
tance of one meter.
ELECTRICAL DATA
Motor IE2
VARIANTS:
Model
RS 64/M MZ
Type
882 T80
Output
(1)
Max.
kW
400 - 850
345 - 730
Mcal/h
Min.
kW
150
130
Mcal/h
Fuel
Gas natural: G20 - G21 - G22 - G23 - G25
G20
G25
- Net calorific value
kWh/Sm
3
Mcal/Sm
3
9.45
8.2
8.13
7.0
- Absolute density
kg/Sm
3
0.71
0.78
- Max. delivery
Sm
3
/h
90
104.5
- Pressure at max. delivery
(2)
mbar
15.3
22.5
Operation
• On-Off (1 stop min each 24 hours).
• Progressive two-stage or modulating by kit (see ACCESSOIRES).
Standard applications
Boilers: water, steam, diathermic oil
Ambient temperatur
°C
0 - 40
Combustion air temperature
°C max
60
Noise levels
(3)
dBA
76
Model
RS 64/M MZ
Type
882 T80
Electrical supply
V
Hz
230 - 400 with neutral ~ +/-10%
60 - three-phase
Electric motor
rpm
W
V
3475
1100
230 - 400
Operating current
A
4.3 - 2.5
Ignition transformer
V1 - V2
I1 - I2
230 V - 1x15 kV
1 A - 25 mA
Electrical power consumption
W max
1500
Electrical protection
IP 40
Blast tube lenght mm
250 - 385
COUNTRY
CATEGORY
IT-AT-GR-DK-FI-SE
II
2H3B/P
ES-GB-IE-PT
II
2H3P
NL
II
2L3B/P
FR
II
2Er3P
DE
II
2ELL3B/P
BE
I
2E(R)B,
I
3P
LU-PL
II
2E3B/P
GB