20102152
26
GB
Installation
4.13.3 Installation of shielded cables
In the case of clamp type
A
:
unscrew the screw until space is created for inserting the
shielding of the shielded cable A1)(Fig. 26);
insert the shielded cable with the shielding inside the
clamp A2);
screw in the screw until it is completely tightened on the
shielding A3).
In the case of clamp type
B
:
pull the indicated tabs upwards and lift until locked in the open
position B1)(Fig. 26);
insert the shielded cable with the shielding inside the
clamp B2);
put pressure on the indicated part until the clamp closes auto-
matically on the shielding B3).
4.13.4 Speed sensor adjustment
WARNING
Do not overtighten.
B1
A
B
B2
A1
A2
B3
A3
Fig. 26
20131950
WARNING
The measurement of speed sensor 1)(Fig. 27) must
be respected!
WARNING
It is important that the disc 2) is installed on the
burner as shown in the Fig. 27.
20072222